Evaluation and display of measured values by means of the DL3. Further interfaces are to follow.
The CS-I global irradiation sensor is used for precise and reliable measurement of solar irradiation. It converts the irradiation measured proprotionally into an interference-resistant 4 ... 20 mA signal. Tekniset tiedot:
Power supply: 12 V DC or 24 V DC Ingress protection: IP 67 Ambient temperature: -40 ... +75 °C Material: PVDF, VA, 1.4301, 1.4305 Measuring range: 0 ... 1500 W/m2 Power consumption: up to 10 mA Reference conditions: +25 °C +/- 5 K Response time: < 1 s Accuracy: +/- (5 % + 10 W/m²) Temperature dependence: < 0,1 % / K (-10 ... +70 °C) Long-term stability: < 2 % per year Output: 4-20 mA
Short-circuit proof
Loop resistance ? 650 ? Cable leads: 3 x 0,5 mm2 silicone-based, CuSn Temperature range: -50 ... +180 °C